Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD MARRIOTT/BALLANTYNE
Address15635 DON LOCHMAN LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/19/2018
Final Score @ Grade
8
General CommentsAquastar 6HP Skimmer equalizers observed in pool, records show aquastar A10RCFR101. No suction hazard present, but must update information asap (within 1 week) to avoid suspension of permit due to lack of adequate documentation for pool. Main drain covers (paramount SDX retro) expire May 2019. Update PDSC for approval to avoid permit suspension. If pool floor and stairs are redone, ensure regulation is in compliance. (4) The leading edge of stair treads shall be marked with a contrasting color band or line at least two inches (5 cm) wide visible from above the stairs. Use of contrasting color tiles installed in the stair tread is acceptable provided the tiles are spaced no more than one inch (2.5 cm) from the edge of the tread or from adjacent tiles. 15A NCAC 18A .2514 MATERIALS OF CONSTRUCTION (a) Pools and appurtenances shall be constructed of materials which are inert, non-toxic to man, impervious and permanent, which can withstand design stresses and which can provide a water-tight tank with a smooth and cleanable surface. Use of vinyl liners is prohibited; however, liners no less than 60 mil thick may be used provided the underlying pool shell is of approved construction. If this material is used for repairs, the existing pool shall be remodeled in accordance with this Rule. (b) Sand or earth bottoms are prohibited in swimming pool construction. (c) Pool finish, including bottom and sides, shall be of white or light colored material determined visually to contrast least with a value of gray whiter than 50 percent black on an artists gray scale, or shown by reflectance testing to reflect more than 50 percent of visible light. (d) Pool surfaces in areas which are intended to provide footing for bathers including steps, ramps, and pool bottoms in areas with water less than three feet deep, shall be designed to provide a slip-resistant surface.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(i) Water in restrooms shall not exceed 110 F.