Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD BY MARRIOTT
Address16700 NORTHCROSS DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2025
Final Score @ Grade
24
General CommentsInspection conducted with Manager Brenton Clark and CPO Darrel Chapman. Electrical permit E4773491 passed inspection 4-7-2025. Verified PDSC information for newly installed main drains. Hose bibbs not observed in restrooms. Ensure hose bibbs are available for cleaning the floor. New Eco Lab chlorinator. Water line to chlorinator leaks, got 7.8 for pH. Recommend having chlorinator recalibrated and fittings checked. Pre-permit inspection did not pass 5) 24) Re-inspection fee paid, re-inspection scheduled for tomorrow at 12:00 PM.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent temperature, total alkalinity, or main drains checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions. - Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed two new ring buoys and throw ropes. Ropes too long. .2530(a) Provide USCG approved ring buoy with attached 24 foot throw rope at least 1/4” inches diameter. - Corrected.
22 6 Premises: emergency telephone provided No No No Incorrect dialing instructions and pool phone number posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap not closed. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected. Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Pre-permit item. Flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restroom 126.6 F. .2526(i) Water in restrooms shall not exceed 110 F.