5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent temperature, total alkalinity, or main drains checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder loose. .2521 Install ladders per manufacturer instructions. - Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed two new ring buoys and throw ropes. Ropes too long. .2530(a) Provide USCG approved ring buoy with attached 24 foot throw rope at least 1/4” inches diameter. - Corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect dialing instructions and pool phone number posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum cap not closed. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected.
Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Pre-permit item.
Flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restroom 126.6 F. .2526(i) Water in restrooms shall not exceed 110 F. |