Inspection Date 9/25/2023
Final Score @ Grade
28
General CommentsPre-permit inspection conducted with Manager Felicia Allen and CPO Darrell Chapman. Darrell is the new CPO for this pool. Updated CPO information in CDP. Pool heater currently turned off. Ensure that if pool is heated temperature is maintained at no more than 90F and temperature is checked and recorded daily in pool log book. New 3/4 HP pump motor installed. G.S. 130A-2(3) Ensure all electrical work is completed by a licensed electrician and an electrical permit and passing inspection are obtained from Code Enforcement - Pre-permit item. Pre-permit inspection did not pass 2) 3) 8) 22) G.S. 130A-2(3) There is a $100 re-inspection fee that will need to be paid prior to rescheduling by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No 0.4ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Pre-permit item.
3 6 Water quality: pool water pH No No No PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Both skimmer baskets cracked. .2518(k) Replace missing or damaged skimmer basket. - Operator able to replace one of the baskets. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Incorrect dialing instructions posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item. 911 did not have any information for the phone. .2530(f) Emergency must remain operable, and be able to electronically transfer Automatic Number and Locator Identification for the phone. - Pre-permit item.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower sign not posted. .2526(a) Post a shower sign visible upon entrance to the pool.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restroom 113F. .2526(i) Water in restrooms shall not exceed 110 F.