21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Pool room very humid. Not able to determine if there is any air movement. .2524(f) Indoor pools shall have mechanical ventilation. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter missing bobber. .2518(g) Install flow meter on return line per manufacturer instructions. - Corrected. Operator installed a different flow meter.
New flow meter installed only reads up to 70 GPM. Flow meter reads 64 GPM. .2518(g) Flow meter be capable of measuring 1.5 times the design flow rate. - Will follow up to ensure that facility has a flow meter that meets requirements. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Difficult to access equipment due to low ceiling height and other items. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower sign not posted. .2526(a) Post a shower sign visible upon entrance to the pool. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restroom 117.5F .2526(i) Water in restrooms shall not exceed 110 F. |