| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) pH 8.2. Maintain pH at 7.2 to 7.8. Corrected to 7.7. Muriatic Acid added directly to the pool to reduce the pH. Keep pool closed for at least one turnover of the pool so chemicals can fully mix. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Incomplete record keeping. Provide record keeping including daily records of Cl, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) One weir missing. Replace missing weir. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone not functioning. Provide functional emergency phone. Corrected by operator. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Pool switched from using stabilized chlorine to CCH chlorinator. Provide documentation to Environmental Health showing that it is an NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Flow meter stuck. Keep flow meter operational. - Intent to suspend item.
.2518(e) Spare pump basket not observed. Provide a spare basket for pump. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(3) Fan in pump room tied to light switch. Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Backwash a direct connection. Filter backwash shall be discharged through an air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
.2626(a) Post a shower sign visible upon entrance to the pool. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2626(i) Water in restrooms shall not exceed 110 F. |