Return to Inspections
NameCOURTYARD BY MARRIOTT
Address16700 NORTHCROSS DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/5/2018
Final Score @ Grade
36
General CommentsFiles updated to reflect that Kieth Wilson is now the CPO. Thermometer in the skimmer is broken. Replace. Underwater light not functioning. Recommend having functional underwater lighting for the pool. Intent to suspend issued. 5) 8) 23) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) pH 8.2. Maintain pH at 7.2 to 7.8. Corrected to 7.7. Muriatic Acid added directly to the pool to reduce the pH. Keep pool closed for at least one turnover of the pool so chemicals can fully mix.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Incomplete record keeping. Provide record keeping including daily records of Cl, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) One weir missing. Replace missing weir. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone not functioning. Provide functional emergency phone. Corrected by operator.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Pool switched from using stabilized chlorine to CCH chlorinator. Provide documentation to Environmental Health showing that it is an NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Flow meter stuck. Keep flow meter operational. - Intent to suspend item. .2518(e) Spare pump basket not observed. Provide a spare basket for pump. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(3) Fan in pump room tied to light switch. Provide continuous forced ventilation or cross ventilation in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Backwash a direct connection. Filter backwash shall be discharged through an air gap.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2626(a) Post a shower sign visible upon entrance to the pool.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(i) Water in restrooms shall not exceed 110 F.