36
General Comments21) Underwater light not functioning. Recommend having functional underwater lighting for the pool. 22) Emergency phone automatically connects to 911, took at least 30 seconds to connect. Recommend adjusting phone such that phone connects to 911 in a more timely fashion. Immediate suspension issued. 2) 3) Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Cl 0.2. Maintain at least 1ppm free chlorine. - Immediate suspension item.
3 6 Water quality: pool water pH No No No pH < 6.8. Maintain between 7.2 and 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity records. No daily maintenance activities recorded. Check daily Cl, pH, temperature, main drains and daily maintenance activities. Check at least weekly Total Alkalinity and Cyanuric Acid if used. If used, maintain cyanuric acid at no more than 100 ppm. - Intent to suspend item
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand on the pool bottom. Clean pool regularly. Ensure filter is in good working order.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer missing weir. Install functional weir.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in pump room. Fix leak. Fan tied to light switch in chemical storage room, light and fan were off. Fan shall run continuously. Recommend having fan on it's own switch.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Provide signage directing bathers to shower before entering the pool.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restroom > 110F. Maintain at no more than 110F.