Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD BY MARRIOTT
Address16700 NORTHCROSS DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/16/2017
Final Score @ Grade
30
General Comments16) Card reader for pool area not working. Recommend fixing card reader. 21) Very strong chloramines in the pool/spa area. Recommend increasing the amount of ventilation in the pool/spa area. Intent to suspend issued: 5) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.9. Maintain between 7.2 and 7.8. Corrected to 7.3.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent Total Alkalinity records. No Cyanuric Acid records. Pool using stabilized chlorine. Check at least weekly Total Alkalinity and Cyanuric Acid. Maintain CYA at no more than 100ppm. - Intent to suspend item. No records of pool maintenance activities. Record any maintenance activities such as chemical additions and filter backwash cyles. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one weir. Install functional weir.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back door not self-latching. Ensure door is self-closing and self-latching. - Intent to suspend item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Underwater light does not work. Pool is open after dark. Provide sufficient lighting such that all parts of the pool floor are easily visible when operating.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace. Provide spare pump basket for pool pump. None observed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical storage room fan tied to light switch. Provide either continuous forced air or cross ventilation in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.