| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH < 6.8. Maintain between 7.2 and 7.8. Corrected to 7.5. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Incomplete record keeping. Missing some days. No recent total alkalinity checks. Check daily Cl, pH, Temperature, Main Drains and at least weekly Total Alkalinity and if used Cyanuric Acid. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with heavy lint buildup. Clean skimmer baskets regularly. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back door propped open. Door to remain closed. Door not self-closing and self-latching. Ensure that door is self-closing and self-latching. - Intent to suspend item. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Underwater light not functioning. Provide functional underwater light. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
No dial tone at phone. Provide functional emergency phone. Phone replaced by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Inadequate ventialtion in pump room. Provide either cross draft or forced air ventilation.
Fan not working in Chemical storage room. Provide continuous forced air ventilation in chemical storage room.
Light not functioning in chemical storage room. Provide functional lighting in chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Provide air gap for backwash. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water > 110F in restroom. Maintain at 110F or less. |