1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Chlorine in pool read 0.6 ppm. Operator added super shock quick. Chemical company also arrived. CDI - Pool read 6 ppm after corrections. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed total alkalinity records not maintained for the last 6 months consistently. Records must be maintained once a week. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Missing one of the two weirs. Replace. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope on buoy tangled. CDI - Rope untangled during inspection. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not working. Missing sign indicating where phone is. CDI - Phone repaired and working. Sign placed. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed two bottles of glue stored on top of sodium bicarb. Move cans. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash discharge pipe is protruding into ground. Air gap is needed. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower sign missing. Hot water in bathrooms read 128F. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed fill spout protruding 4 inches out on the pool. Fill spout shall not protrude more than 3 inches into the pool. |