NameCOFFEY CREEK APARTMENTS
Address2208 YAGER CREEK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/27/2026
Final Score @ Grade
24
General CommentsConducted inspection with CPO. CPO states pool is currently closed but EHS did not observe signs on open gate. Intent to suspend issued for missing floor fitting and inconsistent records. Call EHS Devon when items have been corrected 7049981122. Items must be corrected within 30 days or permit may be suspended. EHS recommends lowering chlorine for bather comfort. Permit Restriction: Flow meter required. Flow required at 100 gpm to meet turnover and not exceed restriction of returns. Flow greater than 119 gpm exceeds the main drains. Suction Hazard. Note - Aftermarket pump installed with model SPX3206Z1VSPE. Same pump/pump curve as SP3206VSP & SP32950VSP per Hayward Night swimming expired and property not seeking re certification. Const. Date: 5/1/1990 Rope Length: 30'0 Night Swim?: No

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. .2535(11) Provide weekly recordings for cyanuric acid and total alkalinity. Records inconsistent and missing daily maintenance drain checks. Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 missing inlet cover on pool floor. Replace. Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment should be conspicuously and conveniently located. Ring buoy rope tangled and inaccessible. Operator corrected. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too long. Operator shortened to approved 30ft. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Front gate not self latching. Operator repaired. No permit action. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Some windows missing limiters. Operator replaced. No permit action.
18 4 Premises: lifeguards present or warning signs posted No No No Property not approved for night swimming and are not seeking to renew. Change signage from hours of 10am to 10pm to Dawn to Dusk.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical storage in pump room. Pool built 1990. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.