NameCOFFEY CREEK APARTMENTS
Address2208 YAGER CREEK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/30/2015
Final Score @ Grade
26
General Comments#8 Some floating debris. ** Remove. #27 Backwash pipe inserted down into sump (pipe has slits). ** Backwash water should discharge through a complete air gap. #29 Hot water ~113F @ lavatories in restrooms. ** Maximum is 110F. Immediate Suspension issued for #3 & #15. Pool cannot open without written approval from the Meck. Co. Health Dept. In order for new pool permit to be issued, the PDSC form must be submitted & approved by the MCHD.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH @ 7.0. ** Maintain 7.2 to 7.8. (immediate suspension)
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Scum/ sediment on pool wall tiles. ** Clean.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope on ring buoy dry rotted. ** Replace. (immediate suspension)
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Decks chipped. ** Repair. Some narrow deck drain covers broken/ missing. ** Replace.
18 4 Premises: lifeguards present or warning signs posted No No No Sign states "CHILDREN UNDER THE AGE OF 18 SHOULD NOT USE THE POOL WITHOUT ADULT SUPERVISION". Sign must state "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION". ** Provide correct signage (in at least 1" letters).
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Forced air vent in equipment/ chemical room operates off light switch. ** Provide continuous forced air ventilation.