NameCOFFEY CREEK APARTMENTS
Address2208 YAGER CREEK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/5/2014
Final Score @ Grade
18
General Comments#25 Observed small water leak @ pump. **Per CPO, waiting on a part to fix. Observed that forced air vent in equipment/ chemical room operates with light switch. **Fan should run continuously. GC #29 Observed hot water @ ~114.3F @ lavatories in restrooms. **Maximum temperature of 110F allowed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed some scum on pool wall tiles. **clean. Observed some sand on pool floor. **vacuum.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed areas where the deck surface has chipped/ is chipping. **repair. Observed pieces of narrow deck drain covers that have broken off. **replace pieces where needed. Observed holes in deck to hold volley ball net poles. **install plugs.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Bottom of 1 pool wall light will not secure properly to eliminate gap. **correct/ replace light assembly if needed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed fitting for hose in vacuum port. **fitting removed & plug put in place while on-site. See .2518(f)
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash discharge pipe extends down into circular sump. **backwash water should discharge through a complete air gap.