Inspection Date 5/28/2014
Final Score @ Grade
32
General Comments#17 Install plugs in holes for volley ball net poles. GC #23 Chlorine feeder must be operating properly - no chlorine tablets allowed in skimmers. **EHS to make return visit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed chlorine tablets in 3 skimmers. **removed while on-site. Proper chlorine level must be obtained via automatic feeder.
3 6 Water quality: pool water pH No No No Observed pH @ 7.1. **pH raised to 7.3 while on-site.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed scum on pool wall tiles. **clean.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ~32" rope on ring buoy. (repeat) **rope shortened to required length (30') while on-site.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool wall light misaligned creating gap. (repeat) **corrected while on-site, maintain.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Observed fitting for hose in vacuum port. **this fitting removed & proper protective cap/plug installed while on-site.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash discharge pipe extends down into circular sump. **backwash should discharge through complete air gap.