Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8.
PH observed at 8.2. Operator corrected to 7.7. No permit action. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide weekly recordings for cyanuric acid and total alkalinity.
Two recent CYA/TA readings missing. All other records complete and accurate. Ensure consistent weekly recordings of CYA and TA. No permit action. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Skimmers full of leaves. Operator emptied. No permit action.
.2518(k) Replace missing weirs.
Two out of six weirs missing. Replace. No permit action. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
3 1/2 ft depth marker missing near clubhouse pool entry on decking. Operator replaced and re caulked tile down. No permit action. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
Three windows not fitted with limiters. Operator added limiters and corrected.
Basketball court windows have plexiglass covering windows from the inside and windows are not accessible by inside patrons.
Windows leading to pool deck from maintenance room do not have limiters. Maintenance room locked and only accessible by maintenance.
No permit action.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Brick part of fence by left side of clubhouse too short due to landscaping. Operator cleared out landscaping.
Other parts of the fence (especially the left side) also has excess landscaping at bottom of fence. Pool built in 1998. Clear out excess landscaping prior to 2027 permitting season. No permit action. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Furniture within 6’ of pool. Moved and corrected. No permit action. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
Signage missing word “THE”.
Operator printed new temporary compliant sign. No permit action. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep the flow meter operational.
Flow meter not operational. Operator corrected. Flow meter reads 160gpm. No permit action. |