NamePRESERVE AT BALLANTYNE, THE
Address11280 FOXHAVEN DRIVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/7/2023
Final Score @ Grade
12
General Comments30 day Intent to Suspend (ITS) issued for pool wall, tiling/coping, windows onto pool deck and gate openings, greater than half inch around latching mechanism. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Also, need to verify night swimming. Send verification to Marie Daley or schedule night swimming visit for renewal of night swimming permissions. Note: Main drains and skimmer equalizer line covers expire Dec 2024. Ensure updates are made and PDSC updated for approval, prior to expiration to avoid permit action.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool wall tiling chipped out under coping, very sharp at corner. .2537 No loose coping, keep in good repair *Permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Windows onto pool deck open more than 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.**Permit item Magna latch below 54" in height. Gaps greater than 1/2" within 18" observed around latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.**Permit item Fence less than 48" in height in some areas. Horizontals less than 45" in height on fence in some areas. Pool built 1998. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items within 3’ of equipment in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water over 110 F in men’s restroom. .2526(i) Water in restrooms shall not exceed 110 F.