Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool wall tiling chipped out under coping, very sharp at corner. .2537 No loose coping, keep in good repair
*Permit item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Windows onto pool deck open more than 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.**Permit item
Magna latch below 54" in height. Gaps greater than 1/2" within 18" observed around latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.**Permit item
Fence less than 48" in height in some areas. Horizontals less than 45" in height on fence in some areas. Pool built 1998.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some items within 3’ of equipment in pump room.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water over 110 F in men’s restroom.
.2526(i) Water in restrooms shall not exceed 110 F. |