Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRESERVE AT BALLANTYNE, THE
Address11280 FOXHAVEN DRIVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/9/2020
Final Score @ Grade
12
General CommentsVerified the following: Pump is IntellifloVS 011018 Main drains: (2) Paramount SDX2 Skimmer equalizer covers: (6) Aquastar 6HPHA Filters: (2) TR100 c Piping is 2.5" for skimmers and main drains, out of ground. Gates do not meet current code. Magna-latches are located less than 54" in height on inside of gate. There are gaps are greater than 1/2" within 18" of latching mechanism in some areas on some gates. This item may require correction to avoid permit action. Tim Dutcher and Chris Elmore will make return visit for this item, since pool was permitted in this condition for 2019 pool season. Operator requested a different inspector. Pool will NOT be permitted for Night Swimming without an additional visit made before dawn or after dusk for this permitting season.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weirs missing at time of inspection. .2518(k) Replace missing weirs. Operator replaced and corrected. Leaves and debris in skimmers. Debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Magna latch below 54" in height. Gaps greater than 1/2" within 18" observed around latching mechanism. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Fence less than 48" in height in some areas. Horizontals less than 45" in height on fence in some areas. Pool built 1998. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No spare pump basket at time of inspection. .2518(e) Provide a spare basket for pump.