Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePRESERVE AT BALLANTYNE, THE
Address11280 FOXHAVEN DRIVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/9/2019
Final Score @ Grade
12
General CommentsPOOL IS PERMITTED FOR NIGHT SWIMMING. POOL HAS AQUASTAR 6HP EQ LINE COVERS. AQUASTAR HAS CHANGED THE CERTIFIED FLOW RATE FOR THESE COVERS TO 92GPM. THESE COVERS EXPIRE APRIL 2020. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM. THE MAIN DRAINS WILL ALSO EXPIRE MARCH 2020. WHEN THESE ITEMS ARE REPLACED, NEW P.D.S.C. PAPERS WILL HAVE TO BE SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL OF THE NEW EQ AND MAIN DRAIN COVERS. BE ADVISED THAT THE EQ LINES CAN BE PLUGGED IN THE POOL AND SKIMMER, WITH THE WATER REMOVED FROM THE LINE, IF THAT IS DESIRED. P.D.S.C. FORMS AND MAIN DRAIN REPLACEMENT WOULD STILL BE REQUIRED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No OBSERVED CYANURIC ACID RESULT MISSING FROM THE LOG BOOK FOR THE WEEK OF 9/1/2019. CYANURIC ACID, IF USED, MUST BE TESTED AND RECORDED AT LEAST ONCE EVERY WEEK. IT CANNOT BE ALLOWED TO BE HIGHER THAN 100PPM. ALL OTHER TEST RECORDS WERE IN ORDER. NO PERMIT ACTION TAKEN. CORRECT THIS ISSUE.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No OBSERVED 1 WEIR MISSING. THERE ARE 6 SKIMMERS TOTAL. NO PERMIT ACTION TAKEN. REPLACE THE WEIR.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No OBSERVED FENCE TO NOT BE TO CURRENT SPECIFICATIONS. OBSERVED SOME AREAS TO BE LOWER THAN 48 INCHES HIGH (46 INCHES IN SOME LOCATIONS). CONSTRUCTION WAS PRIOR TO 2010. NO PERMIT ACTION TAKEN.