Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDRURY INN & SUITES POOL
Address415 W W T HARRIS BLVD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/3/2022
Final Score @ Grade
20
General CommentsInspection conducted with inspector Hannah Howard and CPO Steve Hoyt. Labels not observed on spa pumps. Verified that pump is a Sta-Rite pump with 2 HP motor. Pool safety signage is only posted in the outdoor pool area. Recommend providing safety signage in the indoor pool area as well. Emergency phone number calls back to front desk. Ensure that someone is at the front desk whenever the pool is open. Outer rope on ring buoy starting to fray. Recommend replacing with US Coast Guard approved ring buoy and 33 foot throw rope.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing 1 of 3 weirs. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladders loose. .2521 Install ladders per manufacturer instructions. Some ladders extend > 6” into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plate. .2521 Install handrail per manufacturer instructions.
22 6 Premises: emergency telephone provided No No No Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leaky valve near spa heat exchanger. .2533(d) Pump room floor shall be kept dry and free of standing water.