Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDRURY INN & SUITES POOL
Address415 W W T HARRIS BLVD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/20/2021
Final Score @ Grade
16
General CommentsInspection conducted with inspector Rachel Santimaw and pool operator Steve. Due to COVID-19 precautions, inspection was not signed by the operator. Outside ring buoy damaged. Recommend replacing with US Coast Guard approved ring buoy with 33 foot throw rope. Equalizer line covers expire February 1, 2021. Replace with APSP-16 2017 approved covers or abandon the equalizer lines per state guidelines. Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.” Intent to suspend issued. 21

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing two weirs. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladders loose. One missing an endcap. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Underwater light partially popped out of the niche. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Intent to suspend item.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.