| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Log book without weekly alkalinity records. Missing some weeks. Record total alkalinity weekly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Light protruding from pool wall in outside pool area. Repair light to wall. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir missing in outdoor skimmer and one skimmer with debris in basket. Replace skimmer weir and keep skimmer baskets clean of debris to allow for proper circulation. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Multiple ladders with >6" from pool wall to ladder rung. Maintain 3" to 6" between pool wall and ladder rung. One ladder missing end cap. Provide end cap to prevent damage to the pool wall. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One return fitting missing eyeball. Replace eyeball fitting. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
One ring buoy rope at 31 ft. and other ring buoy rope to short due to tied off rope. Replaced with 33 ft. rope during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Outside gate locked. No key available. Gate shall self-close, self-latch. Latching mechanism less than 54". Provide no opening greater than 1/2" within 18" of latch mechanism. Repair gate to self-close, self-latch with no opening greater than 1/2" wihtin 18" of latch mechanism. If approved by Code Enforcement, gate can be made not a gate and part of the pool barrier by removing latching mechanism and securing permanently. Intent to Suspend issued.
Fence at <48" around outside pool. Maintain 48" or greater for fencing.
Trash can located outside of pool barrier outside provides foothold. Eliminate foothold. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Maintain a functional flow meter. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Plastic container in pump room with no label.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
No shower sign posted. Post visible upon entry to swimming pool on inside and outdoor pool areas. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Fill line manual fill through check valve. Does not meet ASSE rating of .2512 (listed as ASSE1015). If ever replaced, replace with approved check valve. |