Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRENAISSANCE CHARLOTTE SOUTHPARK
Address5501 CARNEGIE BOULEVARD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/18/2019
Final Score @ Grade
14
General CommentsPool has HP6 EQ covers. Aquastar has changed the flow rating for this cover to 92GPM on the wall. The previous flow rate was 224GPM. The pump flow rate for this pool (Pentair Challenger CHII-N1-2F, 2HP) is 139GPM. The HP6 covers expire in December 2020. The new covers must be flow rated to handle the pump flow rate. This pool has 2 insignias, one on the top tread of the stairs and another on the bottom of the pool. It has been determined that some types of insignia, based on color, size, and placement, require removal under State law. This insignia will be evaluated and if the removal of the insignia is required, the Health Department will let the facility know.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed sand on the pool floor. This is not currently a hazard, but may indicate a problem with the sand filter. Have the filter system evaluated for problems. Keep the pool floor clean. No permit action taken.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed 1 eyeball fitting missing the nozzle. Repair the fitting. No permit action taken.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No OBSERVED DOOR ALARM SWITCHED OFF/NON-FUNCTIONAL. DOOR MUST HAVE AUDIBLE ALARM AS IT DOES NOT SELF-LATCH. ALARM WAS SWITCHED ON. -C.D.I. THIS IS A REPEAT VIOLATION FROM THE PREVIOUS INSPECTION. ENSURE THAT THE DOOR ALARM IS KEPT FUNCTIONAL.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at the backwash line.