3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH to be 8.1. pH shall be 7.2-7.8 to be in required safe range. Corrected pH to 7.5. -CDI |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed 1 broken eyeball return fitting. Repair it. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed buoy rope to be 20ft. long. Rope corrected to 24ft. -CDI |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck must have 5ft of clear space. Items were too close to water. Items were moved. -CDI |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed 911 phone non-functional. 911 Phone must work properly. -CDI Phone was corrected. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at back wash line. |