Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD BY MARRIOTT
Address1625 N JOSH BIRMINGHAM PKWY
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/17/2020
Final Score @ Grade
20
General CommentsIntent to Suspend issued for depth marker on deck. Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Observed cyanuric acid listed at 100 ppm on repeated dates. When tested, CYA less than 50 ppm. Ensure accurate record keeping.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Depth marker on pool deck at 4 1/2 ft with "1/2" at 3" in height. Repair so 4" lettering. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Ladder rung >6" from pool wall.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. Light niche with opening >1/2" Corrected during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan in chemical storage room does not appear to be operational.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water in restrooms shall not exceed 110 F. Hot water in restroom >115 F. Maintain at 110 F or below. .2526(k) Provide shatterproof mirrors. Could not verify mirrors as shatterproof in restrooms.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. .2526(c) Floor drains shall be provided in restrooms. No hose bib or floor drain in restrooms.