Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD BY MARRIOTT
Address1625 N JOSH BIRMINGHAM PKWY
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/24/2015
Final Score @ Grade
30
General CommentsImmediate suspension issued.3)6)22)Contact Will Harrison 704-507-6824 for reinspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. Maintain between 7.2 and 7.8. - Immediate suspension item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Equalizer line covers no longer A112 approved covers. Many of the openings painted closed. Install approved A112 covers andsubmit an updated PDSC form. - Immediate suspension item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Underwater light not functioning. Provide functional underwater lights when pool is open.Inadequate ventilation in pool/spa area. My eyes were burning and it was difficult to breathe after having the spa timer on for just 5minutes. Provide proper ventilation for pool/spa area.
22 6 Premises: emergency telephone provided No No No Unable to dial out to 911. Provide functional emergency phone. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water > 110F. Maintain at 110F or less.