| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH @ 6.8. **Maintain pH 7.2 to 7.8.
pH raised to 7.2 while on-site. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
1 (of 2) skimmer does not have any pull. **Check line for obstruction. Resolve. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing 1 end cap. **Install.
Ladder 9.5" to 10" from pool wall. **Clearance should be no greater than 6" (& not less than 3"). **Correct. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Missing 1 inlet fitting. The 3 other inlets have jet fittings. **Install proper "eye ball" fittings on all.
Vacuum port missing protective cap. **Install. Intent to suspend. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter float stuck. **Repair/ replace.
Observed leak in piping near chlorine generator. (salt system no longer in use.) **Resolve. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Forced air vent in chemical room operates off light switch. **Fan should run continuosly. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash pipe discharge point right at top of sump. **Backwash water should discharge through a complete air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed hot water ~120F @ lavatories in restrooms. **Maximum temperature allowed is 110F.
Observed build up under rim of urinal. **Clean. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib in equpment room has no back flow prevention. **Install vacuum breaker. |
|