2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine at 0.7 ppm. Corrected to 3.0 ppm. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed main drain check missing from few days. Record daily. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder 9" from pool wall. Maintain 3" to 6". |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed one inlet fitting missing. Repalce. Vacuum line without cap. Corrected during inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter stuck. Keep operating. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed soda ash on chem room floor. Store up off floor. Fan tied to light switch. Provide continuous ventilation in chem storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at backwash line to pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed water >120 F. Maintain 110 F or below in restrooms. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed hose bib without backflow prevention in pump room. Provide backflow prevention device. |