NameCOURTYARD BY MARRIOTT
Address1625 N JOSH BIRMINGHAM PKWY
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/9/2013
Final Score @ Grade
24
General CommentsPermit not posted. Must be visible upon entrance to pool. Found at meckpools.charmeck.org.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed alkalinity not recorded every week. Record weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed skimmer with build-up. Keep clean.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder rail 9" from pool wall. Maintain no greater than 6".
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed deck furniture 3.5 ft to pool. Maintain 5 ft clearance.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter stuck. Keep operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed fan in chem storage room broken and soda ash bag on floor. Provide adequate storage and keep chemicals up off floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap from backwash line to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed water in restrooms >115 F. Maintain at 110 F or below. Note: No floor drain or hose bibs in restrooms.