NameMECKLENBURG CO AQUATIC CTR SHALLOW
Address800 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/11/2019
Final Score @ Grade
22
General Comments.2530 Emergency phone with slight static. 911 was still audible. Monitor regularly. .2535 Automatic chlorinator could not be verified at time of inspection. Ensure chlorinator properly detects flow. Intent to Suspend issued fo test kit, doors, gutter damage.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed buildup in bottom of cylinders of test kit. Observed several reagents expired. Intent to suspend issued for test kit.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518 (2)(F) The overflow troughs shall be installed completely around the perimeter of the swimming pool except at steps, recessed ladders, and stairs. Observed damaged gutter grate on far side near lifeguard stand. Intent to suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed loose step hand rail at entry point of pool.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed left main exit door at far end past women's locker room not self latching. Observed men's locker room door not self latching. Intent to suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed peeling slip resistant tread around step entry. Repair tread so that it does not continue to worsen. Offset did not warrant intent to suspend.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed chemicals stored in pump room. Move to chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(m) Keep restrooms and fixtures clean and in good repair. One faucet not operational in women's restroom. Men's restroom not viewed at time inspection.