Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMECKLENBURG CO AQUATIC CENTER
Address800 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/2/2025
Final Score @ Grade
20
General CommentsDaniel Osucha present during the inspection. Intent to Suspend issued for: . .2528 - All doors on back side of pool area either sticking or not latching. Repair doors to self-close, self-latch. Office room 12 handle not latching. Repair to self-close, self-latch. .2523/.2537 - replace all wall depth markers where needed to ensure 4" height and not damaged. Screws due to be changed December 2026. Permit Restriction: VFD required at 40 hz, with flow at 2147 gpm based on design flow of pump VFD verified at 40 hz and flow at 2160 gpm.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some debris on pool floor near main drains. Ensure vacuuming to keep pool floor clean.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Multiple depth markers on pool walls damaged so not 4 in. in height. 1) 7 ft. 0 in. near center of the pool on main entry side. 2) (2) 6 ft. 9 in. markers. Replace all depth markers where damaged so 4 in. in height. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Slip-resistant tread beginning to wear off of some starting platforms. Monitor and replace where needed. No labeling on diving boards. .2517 Diving equipment shall be installed in accordance with Rule .2517. Warning signage peeled off on multiple dive platforms. Dive platforms shall have warning signage along with constant monitoring from lifeguard. Replace warning signage on platforms or provide other means to keep inaccessible. Bulkhead with some damage to slip-resistant tread. Monitor and repair as needed if worsens.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Handicap door not closing upon arrival. Working by end of inspection. Door near pump room dog eared back. Corrected to latch during the inspection. All doors on back side of pool area either sticking or not latching. Repair doors to self-close, self-latch. Intent to Suspend issued. Office room 12 handle not latching. Repair to self-close, self-latch. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs on pool deck within 5 ft. of pool edge. Ensure 5 ft. clearance around the pool in all areas.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink not operable in women's restroom. One shower faucet holster damaged in women's shower. Keep all fixtures in good repair.