Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total alkalinity reagent expired. Replaced during the inspection. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Damage to depth markers in multiple locations. Provide 4 ft. contrasting lettering at least every 25 ft. around pool perimeter. Intent to Suspend issued for the following.
1. Replace N where damaged at 7 ft. 4 in. - left side of pool wall.
2. Damage to 4 at 7 ft. 4 in at far side of pool wall.
3. Damage to deck depth markers at N's. Two at far side of pool - 6 ft. 9 in.
4. Damage to ft. on wall 6 ft. 9 in. at far side of pool. 2nd from end of pool. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Slip-resistant tread beginning to wear off of some starting platforms. Replace where needed. No labeling on diving boards. .2517 Diving equipment shall be installed in accordance with Rule .2517. Warning signage peeled off on multiple dive platforms. Dive platforms shall have warning signage along with constant monitoring from lifeguard. Replace warning signage on platforms or provide other means to keep inaccessible. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One double door from pool to lobby not self-latching. Only latches sometimes. Right door near pump room not self-latching every time. Repair doors to self-close, self-latch. Intent to Suspend issued.
Note: Roll-up door remains locked from inside and is maintenance gate. Automated system only controlled by employee's/pool operator. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage near deck drain near egress doors to outside. Keep flooring in good repair. No offset >1/2". Continue to monitor and repair if worsens.
Slip-resistant tread beginning to wear off bulk head flooring. Continue to monitor and repair as needed. Public does not have access to bulk heads. Flooring shall be slip-resistant.
Some staining on deck around the pool. Does not appear to be slick. Monitor to ensure floor is maintained as slip-resistant.
Some drain flies on pool deck above drain at end nearest to locker room entrance. Keep drains clean and free of insects. Intent to Suspend issued. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One damaged shower clip in family locker room. Repair fixture.
Sink faucet handles with springs not running for full hand wash. Repair faucet handles to ensure proper handwashing can occur. |