Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMECKLENBURG CO AQUATIC CENTER
Address800 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/28/2021
Final Score @ Grade
16
General Comments5 - Test kit tubes with black build-up. Recommend replacing test kit tubes. 6 - One main drain off center. Operator inspected drain covers 10/5 and had to secure to sump. Continue to monitor. Operator stated secure once repaired. 15 - Recommend moving one body hook to opposite side of pool to ensure accessible by patrons at all times. No pressure gauges on filter. Original construction. Daniel Osucha present during the inspection. No signature due to covid restrictions. Intent to Suspend issued for depth markers and pool barrier.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Multiple no diving markers on pool walls worn off/coming off including but not limited to: - 7 ft 4 in on grand stand side. - 12 ft. 8 in. on both sides. - 11 ft 10 in and 7 ft 8 in by outside egress near grand stand side Replace depth markers on pool wall where needed. Intent to Suspend issued. >25 ft. between wall depth markers at 6 ft 9 in. center and to left of center. Maintain 25 ft. between wall depth markers. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No 11 - Slip-resistant tread beginning to wear off of some starting platforms. Replace where needed. No labeling on diving boards. .2517 Diving equipment shall be installed in accordance with Rule .2517. Warning signage peeled off on multiple dive platforms. Dive platforms shall have warning signage along with constant monitoring from lifeguard. Replace warning signage on platforms or provide other means to keep inaccessible.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Multiple doors not self-closing, self-latching or self-closing with audible alarm. Repair to self-close, self-latch or self-close with audible alarm. Intent to Suspend issued. 1. Men's and women's doors from locker rooms. 2. Multi-purpose room. 3. Office rooms 116 and 114. Note: Roll-up door remains locked from inside and is maintenance gate. Automated system only controlled by employee's/pool operator.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some damage near deck drain near egress doors to outside. Keep flooring in good repair. No offset >1/2". Continue to monitor and repair if worsens. Slip-resistant tread beginning to wear off bulk head flooring. Continue to monitor and repair as needed. Public does not have access to bulk heads. Flooring shall be slip-resistant. Some staining on deck around the pool. Does not appear to be slick. Monitor to ensure floor is maintained as slip-resistant.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Sink faucet handles with springs not running for full hand wash. Repair faucet handles to ensure proper handwashing can occur. One sink missing handle in the family restroom. Keep all fixtures in good repair.