NameMECKLENBURG CO AQUATIC CENTER
Address800 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/29/2020
Final Score @ Grade
14
General Comments22 - Emergency phone not clearly audible. 911 indicated they could barely hear inspector. Given 30 days to repair phone so clearly audible. 29 - Some sink faucet handles not staying on when pushed. Repair to ensure proper handwashing can occur. Note: Chlorinator verified to detect flow during inspection. Note: Facility was vacuuming at time of inspection. Instructed staff to not vacuum while pool is open to the public. Portable vacuum used. Intent to Suspend issued for depth markers and doors on to pool deck.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Two 6 ft. 9 in. depth markers on pool walls on either side damaged. Replaced where needed. Intent to Suspend issued. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder handrail loose closest to large doors by storage area. Keep handrails tight and in good repair. .2521 Install ladders per manufacturer instructions. No labeling on diving equipment. .2517(a)3 Provide labeling affixed to diving equipment. Some Danger labeling on diving platforms not in place or damaged. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from main entry area and right family restrooms not self-closing, self-latching. Repair to self-close, self-latch. Intent to Suspend issued. .2537(b) All gates and doors shall be self-closing, self-latching.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some damage to slip-resistant tread around bulkhead where diving platforms are installed. Keep decking slip-resistant. Some anchors around pool deck missing plugs. Corrected during inspection. .2522(g) Decks and walkways shall be slip-resistant. Minor deck damage around drains. Continue to monitor to ensure no offsets >1/2". .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.