9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Sticker depth marker on wall at 6 ft 9 in with damage. Replace depth marker. Intent to Suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
No labeling on diving boards per rule instruction. Diving boards must be installed per manufacturer instruction and labeled per rule .2517. Observed bleachers out and 8 ft clearance around diving boards not maintained. Provide 8 ft. clearance around all diving equipment. Some damage to slip resistant surface on starting platforms. Keep in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Roll-up door propped open. All doors on to pool deck must self-close, self-latch. Door is equipped to be kept locked and shall remain locked when not in use. Intent to Suspend issued. One other door propped open. Keep closed. Corrected during the inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some diving platform anchors and flag anchors missing plugs. Provide no openings in pool deck >1/2". Intent to Suspend issued. Some minor deck damage around deck drains. Keep in good repair. Metals platforms located near warm pool at 4 ft. from pool edge. Maintain 5 ft clearance around pool at all times. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter exceeding permit restriction and flow of pump at 2147 gpm. Flow meter indicating 2300 gpm average. Permit restriction of 40 Hz on VFD. Currently set at 40 Hz. Required adjustment to meet permit restrictions. Intent to Suspend issued. |