Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some debris on main drain closest to pump room. Keep drains free of debris. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Multiple depth markers on pool walls either peeling off or missing parts of ft/lettering. Provide wall depth markers at 25 ft. apart or less in 4" in lettering. Intent to Suspend issued.
>25 ft. between wall/deck depth marker at 11 ft. 6 in. Right side of pool. >25 ft. between wall depth markers (left side of pool closest to pump room). Maintain 25 ft. or less measured around the pool perimeter on wall depth marker. Intent to Suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder handrails not secured at shallow end of pool. Ensure, when in place, they are secure.
Paddock starting platforms measuring at 31" from water level. Platforms shall measure no greater than 30" from water level. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Multiple doors on to pool deck with bell chime as audible alarm. Bells are rusted and are no longer audible. Hard rain occurred during the inspection and bells could not be heard. All doors on to pool deck shall self-close, self-latch or self-close with audible alarm. Intent to Suspend issued.
Door near back restrooms not latching. Repair to self-close, self-latch. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Damage to pool deck near back restrooms with offsets >1/2". Repair decking. Intent to Suspend issued.
Some standing water on pool deck where deck is not sloped to drain. Continue to monitor to ensure that it does not present a slip hazard. Some deck drains with debris. Keep clean. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone number faded off of signage. Corrected during the inspection. Phone verified with callback. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Could not verify chlorinator at time of inspection. Automated chlorinators/acid feeders shall detect flow from the pump and turn off or alarm when no flow. Intent to Suspend issued. Operator must demonstrate flow detection on system. |