Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARBORETUM APARTMENTS
Address7700 ARBORETUM DRIVE
 
City/State/ZIP
CHARLOTTE NC 28270
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/16/2022
Final Score @ Grade
12
General CommentsObserved pump set at 2250 RPM not 2050 RPM. 2050 RPM is required. Setting was corrected. Observe new pipe sections with new flow meter. Flow meter reads 10 GPM. Pool is clear and disinfect is correct. Minimum turnover is listed as 25 GPM and 60 GPM is given as the max flow rate for the piping system.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) The pool operator must maintain records for at least six months. Observed a large number of days with no entry in the log book within the last 6 months of operation. The log book must be properly kept with proper logs for every day the pool is open. This is required and is not optional. I.T.S. Issued. Deadline for correction is 12/16/2022. There must be 30 days of proper records kept including the weekly checks. Failure to keep proper records for the 30 day period may result in pool closure and the requirement to keep records on the closed pool until the Health Department is confident records can be correctly kept.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder feet missing. Replace the ladder feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed fence to be out of current spec on foot holds, gaps under the fence larger than 4 inches, and fence height less than 48 inches at some points. Fence built prior to 2010. No permit action taken.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at the backwash line.