Premises Information

Return to Inspections
NameDOUBLETREE HOTEL
Address2600 YORKMONT RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/25/2024
Final Score @ Grade
12
General CommentsConducted inspection with Andy Thomas. Items corrected by end of inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Some test kit reagents expired. CPO replacing kit. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Battery dead in alarm for ground levels doors, not self-latching or alarmed onto pool deck. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator replaced battery and corrected doors to have audible alarm. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Dry chemicals stored directly on floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.