5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Some test kit reagents expired. CPO replacing kit. No permit action. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Battery dead in alarm for ground levels doors, not self-latching or alarmed onto pool deck.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator replaced battery and corrected doors to have audible alarm. No permit action. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items around equipment and piping. Pool built '89.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Dry chemicals stored directly on floor. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap. |