11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder by 4 1/2 FT loose.
.2521 Install ladders per manufacturer instructions Keep tight and in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gates not self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted to self-close, self-latch. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
When 911 is dialed front desk could not locate emergency call location to route. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
CPO helped with alarm and educated staff on hitting “alarm” then “911 location” for outgoing emergency call to locate emergency call location (pool, ext 5999). Corrected through education. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items around equipment and piping. Pool built '89.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap. |