Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDOUBLETREE HOTEL
Address2600 YORKMONT RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/31/2022
Final Score @ Grade
16
General CommentsOne pool light out, on side without main drains. Operator having repaired 9/3 and sending verification to Marie Daley at 704-507-6806 No Night Swimming until corrected

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder by 4 1/2 FT loose. .2521 Install ladders per manufacturer instructions Keep tight and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates not self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted to self-close, self-latch.
22 6 Premises: emergency telephone provided No No No When 911 is dialed front desk could not locate emergency call location to route. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. CPO helped with alarm and educated staff on hitting “alarm” then “911 location” for outgoing emergency call to locate emergency call location (pool, ext 5999). Corrected through education.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at pool backwash. Pool built 1989. .2513(b) Filter backwash shall be discharged through an air gap.