16
General CommentsITS for gates, ladder and inlet fitting. **Note: Drain covers expire 2021. When Aquastar 6HPs are replaced (expires Feb 2021) flow rating has been reduced to 92 gpm on walls (6HPHAs) and may not meet standard for suction hazard prevention according to max flow rating for pump. Skimmer equalizers will need to be plugged according to state guidance or a different cover found that meets/exceeds standard for pump curve. Main drains expire June 2021. Inspection with: Andy Thomas Report to: Andy.Thomas@hilton.com No signature due to COVID-19

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders removed from side of pool for repair at time of inspection. .2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. *ITS items.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates not self-latching at ime of inspection. Battery dead in alarm for ground levels doors, not self-latching or alarmed onto pool deck. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator replaced batter and corrected doors to have audible alarm. *ITS item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed missing inlet fittings at time of inspection. .2518(i) Provide inlet fittings in good repair. *ITS item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Soap in men's restroom not dispensing at time of inspection. .2526(j) Provide soap and soap dispenser, no glass, at each sink. .2526(m) Keep restrooms and fixtures clean and in good repair. Per housekeeping, due to COVID-19, unable to get correct soap for dispenser and will work if multiple attempts are made. Suggested signage or repair of fixture to work upon use.