Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDOUBLETREE HOTEL
Address2600 YORKMONT RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/18/2020
Final Score @ Grade
12
General CommentsShowers off at time of inspection. **Note: Main drains expire February 2021. When Aquastar 6HPs are replaced (expires Feb 2021) flow rating has been reduced to 92 gpm on walls (6HPHAs) and may not meet standard for suction hazard prevention according to max flow rating for pump. Skimmer equalizers will need to be plugged according to state guidance or a different cover found that meets/exceeds standard for pump curve. Checked lights at time of inspection. Following up with operator regarding chages for Night Swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No cyaniric acid checks at time of inspecction. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and recorded. Corrected.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One inlet fitting coming off of threads on wall. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Operator adjusted. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items around equipment and piping. Pool built '89. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. .2513(b) Filter backwash shall be discharged through an air gap.