Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDOUBLETREE HOTEL
Address2600 YORKMONT RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/24/2019
Final Score @ Grade
22
General CommentsNote - flow rating for 6HP covers have changed to 92 gpm and may not be compatible with pump when due for replacement.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Test kit with black residue on bottom of cyanuric acid test tube. Replace test kit as needed. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder closest to fitness area with rungs 9" to pool wall. Maintain 3" to 6" between wall and ladder rungs. Pool built 1989. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One return missing fitting. Replace return fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope at 16 ft. due to tie off. Corrected to 18 ft. during inspection. General Comment - Grab rope on ring buoy starting to degrade. Still usable. Replace within 30 days. A return visit will be made in 30 days to verify if documentation not provided.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No New chlorinator installed - CCH Endurance - located at entry to the pump room. Provide 3 ft. clearance around all equipment. Operator indicated that Leslie's Pools has already been contacted to move chlorinator. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled in pump room. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Pit is half full of water. .2513(b) Filter backwash shall be discharged through an air gap.