Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDOUBLETREE HOTEL
Address2600 YORKMONT RD
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/20/2016
Final Score @ Grade
22
General Comments#25 Portion of pool chemicals are being stored in new storage building that has 1 high vent at each end of the structure. ** Provide natural cross draft ventilation (1 vent high at end & the other vent low at the opposite end) or forced air ventilation. Note: Computer issues delayed CDP entry. EHS slow on field CDP entry.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Residue/ scum on pool wall tiles. ** Clean. Leaves on pool floor. ** Remove debris.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Corner broken off one skimmer lid. ** Replace lid. Accumulation of leaf debris & snakes (3) in skimmer baskets. ** Check skimmer baskets at least daily & empty. Corrected during inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder 8" from pool wall (& the other 2.5" from pool wall). ** Maintain minimum of 3" & a maximum of 6".
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some lounge chairs & table chair 5' from pool edge. ** Maintain 6' of clear walking space.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter float stuck. ** Keep operational.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Leak @ junction of one shower head fixture & column. ** Resolve.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Over-the-rim fill spout extends ~7.5" beyond pool wall. ** Maximum is 2". Hose bib outside equipment/ chemical room has no back flow prevention device. ** Install vacuum breaker.