11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder >6" from pool wall. Maintain between 3" and 6" between ladder rail and pool wall. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door leading out on to pool deck from the fitness room must remain unlocked due to fire code per engineering. All glass in fitness room is tempered. Door into fitness room is key swipe but does not self-close, self-latch. Door must be made to self-close, self-latch. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to pool coping. Keep in good repair. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in metal storage bin with no ventilation or lighting. Height of ceiling does not meet requirements. Move to approved chemical storage area that meets code or to pump room. |