Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameEMBASSY SUITES HOTEL
Address4800 S TRYON STREET
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/16/2026
Final Score @ Grade
10
General CommentsInspection conducted with PIC Cortez. INTENT TO SUSPEND issued today. Facility has 30 days to bring ITS item into compliance. Please contact EHS Rusi Woo at 704-430-7960 once repaired. Night swimming previously approved. PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 100 GPM DUE TO DRAIN COVER FLOW RESTRICTION. SUCTION HAZARD. 2 HP MOTOR ON 1.5 HP PUMP.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed one ladder missing an endcap. Observed other ladder missing both endcaps. CPO replaced all missing endcaps during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2537(3) There shall be no loose coping. Observed multiple loose coping, damaged/cracked tiles, and offsets greater than half inch on pool deck. INTENT TO SUSPEND ITEM.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Observed chemicals stored in pump room. Pool built in 1989.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash. Pool discharges through pipe under equipment. Pool built in 1989.