General CommentsInspection conducted with Otto Williams. Pool permit issued. Sticker provided during inspection. Permit will be available for printing from the website. A 30 day intent to suspend the permit will be issued for doors leading onto the pool deck not self closing and latching shut or audibly alarmed. EHS will return at 30 days to evaluate all 3 doors leading onto pool deck. At that time, water chemistry will also be evaluated as readings inconsistent.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Missing one of four weirs. Replace. No permit action.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Missing end caps on one ladder. Same ladder with some rust and corrosion may need replacement.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy with rope greater than 36’. Corrected to 33’.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. All three entry doors onto pool deck observed to not be self closing and self latching each time and not alarmed. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Furniture within 5’ of pool. Operator relocated.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items around piping. Water under pump. Pool built in 1989. No backflow at hose bib. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. .2533(d) Pump room floor shall be kept dry and free of standing water.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Pipework re-plumbed needs to be labeled or color coded.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool discharges through pipe under equipment. Pool built '89. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. No soap available in either restroom.