Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameEMBASSY SUITES HOTEL
Address4800 S TRYON STREET
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/20/2020
Final Score @ Grade
22
General Comments6) Water murky, but main drains visible and water quality in compliance. Ensure water clarity allows visibility of main drains at all times.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing step. .2521 Install ladders per manufacturer instructions. .2521(b) Ladders shall have slip-resistant tread.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Small hole, drain port, in pool wall by handicap chair, greater than 1/2" open offset. Cover hole to eliminate offset. Lack of severity does not warrant permit action. Operator is sending verification of correction to Marie Daley 704-507-6806 and item will be checked at next inspection. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. Keep accessible. Operator untangled and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Alarm not working on side door onto pool deck and not latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator adjusted alarm and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room, some on floor. Items around piping. Pool built in 1989. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool discharges through pipe under equipment. Pool built '89. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Men's restroom sink leaking at time of inspection. .2526(m) Keep restrooms and fixtures clean and in good repair.