NameEMBASSY SUITES HOTEL
Address4800 S TRYON STREET
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/12/2019
Final Score @ Grade
24
General CommentsPump motor not grounded at time of inspection. Pump must be grounded and certified by licensed electrician. Pool voluntarily closed until permit pulled.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. .2530(a) Lifesaving equipment should be conveniently located. Operator untangled and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Front door onto pool deck sensor not turning off to allow door to latch within 30 seconds. Back door not self-latching or alarmed. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator installed alarms on both doors to self-close and have audible alarm. Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs and tables within 5' of pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Items moved. Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone not operating at time of inspection. .2530(f) Emergency phone shall remain operable. Operator replaced phone. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room, some on floor.Pool built in 1989. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Men's restroom sink leaking at time of inspection. .2526(m) Keep restrooms and fixtures clean and in good repair. Provide paper towels/hand drying in both restrooms.