Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed Paramount SDX Retros covers with riser ring extending over 2 inches on wall and floor.
Drain outlets shall comply with ASME/ANSI A112.19.8-2007. No drains shall extend over 2 inches.
**Immedate suspension issued
Removed riser rings and replace covers. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed pool floor collecting debris. Observed pool wall tile collecting residue.
Keep pool walls and floors clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 2 skimmers missing weirs.
Keep skimmers in good repair.
**Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed 2 ladders missing end caps.
Replace caps |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed motion sensor on doors. Doors must be self closing self latching, or self closing with an audible alarm.
**Intent to suspend item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed emergency phone connection not consistant. Wall jack damaged not making constant connection.
**Immediate suspension |