Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameEMBASSY SUITES HOTEL
Address4800 S TRYON STREET
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/6/2016
Final Score @ Grade
32
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No chlorine in pool. Pool has saline system. Maintain chlorine at least 1.0 ppm. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some records missing from log books. Maintain chlorine, pH, main drain checks and temperature daily.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder greater than 6" from pool wall and missing end cap. Pool built prior to 2010. Maintain between 3" and 6" from wall to ladder and replace end cap.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Two wall returns missing fittings. Replace.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Severe damage to deck in several locations. Repair decking where needed. 4 ft from pool to wall in several locations. Pool built prior to 2010. Maintain 5 ft clearance around swimming pool.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One light burnt out in swimming pool and dim lighting in pool room. Pool must maintain at least 10 ft candles of light to operate at night.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Coupling broken on piping into pump. Repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leaking valve in pump room. Keep dry and repair line.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floors in restrooms slick. Floors shall be slip-resistant.