5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Thiosulfate reagent expired in test kit. Provide new reagent.
Could not view records for October or previous months. Swimming pool manager out on leave. Provide records for at least September/October showing daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for total alkalinity.
Intent to suspend issued the above items. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Some rust around drain fittings at coping/overflows. Keep fixture fittings in good repair. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Dialing instructions did not match actual instructions for phone. Corrected during the inspection. Signage read dial 9-911. 9 was marked through on signage to reflect actual dialing instructions.
Phone not ringing back when phone number is dialed. Number does go to phone. Phone answered when picked up. Phone shall audibly ring when dialed. Repair by Friday, mid-day, November 8th. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Could not verify automated feeder. No pool manager available. Feeder shall detect flow and turn off with no flow from pump. Intent to Suspend issued. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >114 F. Maintain at 110 F or below. |