5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Missing some main drain checks. Record daily.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Note: Some days with chlorine at 0 ppm and no pool notes for closure and no corrective action (2/13 and 2/12). Ensure pool is closed to public if chlorine is less than 1.0 ppm. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder handrail loose near lifeguard stand.
.2521 Install ladders per manufacturer instructions. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Mirrors in restrooms at sink area not verified as shatterproof. Water in women's locker room >110 F.
.2526(k) Provide shatterproof mirrors.
.2526(i) Water in restrooms shall not exceed 110 F. |